Features & Benefits
Highly reliable
Fully assembled and factory pressure tested to ensure reliability.
Easy installation
Each unit comes ready to install and uniquely labelled saving time on site.
Quick hydronic balancing
The pressure independent solution provides direct setting of the max flow.
Precise flow control
The modulating version provides uniquely shaped EQM characteristic for best modulating control.
Technical Information
Applications:
Heating and cooling systems.
Functions:
Control (EQM or Linear)
Balancing
Pre-setting (max flow/Cv)
Differential pressure control
Measuring (q, T, ∆H)
Shut-off/Isolation function for use during system maintenance – see "Leakage rate"
Bypass
Flushing
Strainer
Pressure class:
PN 16 (230 psi)
Temperature:
Max. working temperature: 194°F
Min. working temperature: 32°F
Media:
Water or neutral fluids, water-glycol mixtures (0-57%).
Leakage rate:
Ball valves: Level A (EN 12266-1/12 - P12).
TA-Modulator, TA-COMPACT-P: Leakage flow ≤ 0,01% of max. qmax (setting 10) and correct flow direction. (Class IV according to EN 60534-4).
Lift:
TA-COMPACT-P: 0.157 in.
TA-Modulator: 1/2" - 3/4" 0.157 in., 1" - 1 1/4": 0.256 in.
Characteristics:
TA-Modulator: EQM, best suited for modulating control.
TA-COMPACT-P: Linear, best suited for on/off control.
Material:
TA-Modulator, TA-COMPACT-P, TA-STR: See separate technical leaflets.
H-bypass valve:
Body: Gunmetal
Closing end nut: Brass CW602N
Stem: Brass CW602N
Stem guiding: PTFE
Stem O-ring: EPDM
Stem nut: Brass CW614N
Ball: Gunmetal
Ball seats: PTFE
Closing cap: Brass CW602N
Closing cap seat: PTFE
Closing cap O-ring: EPDM
Drain: Brass
Sealings: EPDM
Measuring points: AMETAL®
Sealings: EPDM
Marking:
TA-Modulator: TA, IMI, PN 16, DN and flow direction arrow. Grey setting wheel and black identification ring on measuring point: TA-Modulator and DN.
TA-COMPACT-P: TA, IMI, PN 16, DN and flow direction arrow. Grey setting wheel: TA-COMPACT-P and DN.
H-bypass valve: PN, DN. Lever: TA, IMI, opening-closing directions.
Connections:
Internal NPT threads according to ANSI/ASME B1.20.1-1983.
Connection to actuator:
M30x1.5
Actuators:
TA-Slider 160 (for modulating control)
EMO TM (for modulating control)
EMO T (for on/off control)
For more details, see separate technical leaflets.
Articles
Connection system side and load sides (D): Internal NPT threads according to ANSI/ASME B1.20.1-1983.
With strainer – Handles up
Connection system side and load sides (D): Internal NPT threads according to ANSI/ASME B1.20.1-1983.
Drain with 3/4" hose connection. Self-sealed measuring points.
TA-Modulator Size | D | L1 [in] | L2 [in] | Offset (±0.10 in.) | H1 [in] | H2 [in] | T [in] | C-C [in] | qmax [gpm] | lb. | EAN | Article No |
1/2" | 1/2 NPT | 7.93 | 7.93 | 0 | 4.96 | 2.83 | 7.01 | 3.15 | 2.11 | 4.41 | 5902276819001 | 9696-32.805 |
3/4" | 3/4 NPT | 8.27 | 8.27 | 0 | 5.35 | 2.83 | 7.01 | 3.15 | 4.29 | 5.07 | 5902276819018 | 9696-33.805 |
1" | 1 NPT | 9.06 | 9.06 | 0 | 5.55 | 3.07 | 7.72 | 3.15 | 7.71 | 8.38 | 5902276819025 | 9696-34.805 |
1 1/4" | 1 1/4 NPT | 10.4 | 10.4 | 0 | 5.55 | 3.07 | 7.72 | 3.15 | 15.8 | 11.5 | 5902276819032 | 9696-35.805 |
H1 and H2 without actuator.
T = Depth of the device
Connection system side and load sides (D): Internal NPT threads according to ANSI/ASME B1.20.1-1983.
With strainer – Handles up
Connection system side and load sides (D): Internal NPT threads according to ANSI/ASME B1.20.1-1983.
Drain with 3/4" hose connection. Self-sealed measuring points.
TA-COMPACT-P Size | D | L1 [in] | L2 [in] | Offset (±0.10 in.) | H1 [in] | H2 [in] | T [in] | C-C [in] | qmax [gpm] | lb. | EAN | Article No |
3/8" | 1/2 NPT | 7.93 | 8.25 | 0.03 | 4.96 | 2.83 | 7.01 | 3.15 | 0.53 | 4.41 | 5902276819049 | 9696-30.815 |
1/2" LF | 1/2 NPT | 7.93 | 7.93 | 0 | 4.96 | 2.83 | 7.01 | 3.15 | 1.08 | 4.63 | 5902276819056 | 9696-31.815 |
1/2" | 1/2 NPT | 7.93 | 7.93 | 0 | 4.96 | 2.83 | 7.01 | 3.15 | 2.07 | 4.63 | 5902276819063 | 9696-32.815 |
3/4" | 3/4 NPT | 8.27 | 8.27 | 0 | 5.35 | 2.83 | 7.01 | 3.15 | 5.06 | 5.07 | 5902276819070 | 9696-33.815 |
1" | 1 NPT | 9.06 | 9.06 | 0 | 5.55 | 3.07 | 7.72 | 3.15 | 9.46 | 8.38 | 5902276819087 | 9696-34.815 |
1 1/4" | 1 1/4 NPT | 10.4 | 10.2 | 0.02 | 5.55 | 3.07 | 7.72 | 3.15 | 16.3 | 11.5 | 5902276819094 | 9696-35.815 |
H1 and H2 without actuator.
LF = Low flow
T = Depth of the device
Fitted together with the insulation to minimize the risk of condensation at the valve-actuator interface.M30x1,5.
Spindle extension
Fitted together with the insulation to minimize the risk of condensation at the valve-actuator interface.
M30x1,5.
Type | L [in] | EAN | Article No |
Plastic, black | 1.18 | 4024052165018 | 2002-30.700 |
For heating/comfort cooling.Material: EPP.Fire class: E (EN 13501-1), B2 (DIN 4102).
Insulation kit
For heating/comfort cooling.
Material: EPP.
Fire class: E (EN 13501-1), B2 (DIN 4102).
1.18 in. spindle extension included.
For TA-COMPACT-/TA-Modulator versions only.
For size | L [in] | H1 [in] | H2 [in] | Article No |
3/8”, 1/2”, 3/4” | 3.94 | 2.40 | 2.79 | 339010-50502 |
1" | 5.00 | 2.79 | 3.31 | 339010-50602 |