TA-Slider 160 BACnet/Modbus

IMI TA
Compare
​​​​​​​ Digitally configurable proportional push actuator for Bus communication with BACnet MS/TP or Modbus RTU – 36/45 lbf (160/200 N) Digitally configurable actuators for Bus communication with BACnet MS/TP or Modbus RTU, with or without change-over. A wide range of setup options provide extensive flexibility for on-site parameter adaptation. Fully programmable binary input, relay and adjustable max. stroke of the valve bring new opportunities for advanced hydronic control and balancing.

Convenient, reliable setup

Fully customisable by smartphone via Bluetooth using a TA-Dongle.

Fully configurable

More than 200 setup options allow input and output signals, binary input, relay, characteristics and many other parameters to be configured.

Easy diagnostics

Tracks the last 10 errors to allow system faults to be found quickly.

Quick copy of settings

Identical settings can be quickly copied from TA-Dongle to several TA-Slider actuators.

Technical description

Functions:

Proportional control
Manual override
Stroke detection
Mode, status and position indication
Stroke limitation setting
Valve blockage protection
Valve clogging detection
Error safe position
Diagnostic/Logging

BACnet/Modbus version:
+ 1 binary input, max. 100 Ω, cable max. 32.8 ft or shielded.
+ 1 connection for Pt1000 temperature probe.

BACnet/Modbus CO (change-over) version:
+ 1 binary input, max. 100 Ω, cable max. 32.8 ft or shielded.
+ 2 connections for Pt1000 temperature probe.
+ 1 relay, internally wired for control of TA-M106 actuator on TA-6-way valve (max. 2A, 30 VAC/VDC on resistive load).

Supply voltage:

24 VAC/VDC ±15%.
Frequency 50/60 Hz ±3 Hz.
BACnet/Modbus CO:
24 VAC only for enabling powering of TA-M106 actuator.

Power consumption:

BACnet/Modbus:
Operation: < 1.5 VA (VAC); < 1.0 W (VDC)
Standby: < 1.2 VA (VAC); < 0.75 W (VDC)
BACnet/Modbus CO:
Operation: < 1.5 VA (VAC)
Standby: < 1.2 VA (VAC)
TA-M106 actuator consumption must be added separately.

Input signal:

By BACnet/Modbus or with hybrid control mode;
0(2)-10 VDC, Ri 47 kΩ.
Adjustable hysteresis sensitivity 0.1-0.5 VDC.
0.33 Hz low pass filter.
Proportional:
0-10, 10-0, 2-10 or 10-2 VDC.
Proportional split-range:
0-5, 5-0, 5-10 or 10-5 VDC.
0-4.5, 4.5-0, 5.5-10 or 10-5.5 VDC.
2-6, 6-2, 6-10 or 10-6 VDC.
Proportional dual-range (for change-over):
0-3.3 / 6.7-10 VDC,
2-4.7 / 7.3-10 VDC,
0-4.5 / 5.5-10 VDC or
2-5.5 / 6.5-10 VDC.
Default setting: By BACnet/Modbus. If Hybrid mode chosen, default input signal is Proportional 0-10 VDC.

Output signal:

By BACnet/Modbus.

Characteristics:

Linear, EQM 0.25 and inverted EQM 0.25.
Default setting: Linear.

Control speed:

254 s/in (10 s/mm)

Adjusting force:

36/45 lbf (160/200 N)

Self-adjusting for IMI Hydronic Engineering valves.

Temperature:

Media temperature: max. 248°F
Operating environment: 32°F to 122°F (5-95%RH, non-condensing)
Storage environment: -4°F to 158°F (5-95%RH, non-condensing)

Ingress protection:

IP54

(all directions)

(according to EN 60529)

Protection class:

(according to EN 61140)

III (SELV)

Cables:

Separate overmoulded cables (see Additional equipment).
Type LiYCY 5x22 AWG (5x0.34 mm2) (cables A and B) and type LiYY 6x22 AWG (6x0.34 mm2) (cable C).
Halogen free, fire class B2ca – s1a, d1, a1 according to EN 50575.
Relay cable (CO version):
Type LiYY 3x22 AWG (3x0.34 mm2).
3.28 ft, 6.56 ft or 16.4 ft. With connector to actuator TA-M106.
Halogen free, fire class B2ca – s1a, d1, a1 according to EN 50575.

Stroke:

0.27 in (6.9 mm)

Automatic detection of the valve lift (stroke detection).

Noise level:

Max. 30 dBA

Weight:

BACnet/Modbus: 0.48 lb
BACnet/Modbus CO:
0.57 lb, 3.28 ft relay cable
0.68 lb, 6.56 ft relay cable
0.99 lb, 16.4 ft relay cable

Connection to valve:

Retainer nut M30x1.5.

Material:

Cover: PC/ABS GF8
Housing: PA GF40.
Swivelling nut: Nickel-plated brass.

Color:

White RAL 9016, grey RAL 7047.

Marking:

Label: IMI TA, CE, product name, article No. and technical specification.

Certification CE:

LV-D. 2014/35/EU: EN 60730-1, -2-14.
EMC-D. 2014/30/EU: EN 60730-1, -2-14.
RoHS-D. 2011/65/EU: EN 50581.

Product standard:

EN 60730.

Articles - TA-Slider 160 BACnet/Modbus

TA-Slider 160 BACnet/Modbus

Input signal: Via Bus or 0(2)-10 VDC

With binary input and 1 connection for Pt1000 temperature probe

Bus
EAN
Article No
BACnet
5901688823590
322224-13011
Modbus
5901688823538
322224-12011

Articles - TA-Slider 160 BACnet/Modbus CO

TA-Slider 160 BACnet/Modbus CO

Input signal: Via Bus or 0(2)-10 VDC

With binary input, 2 connections for Pt1000 temperature probe and relay 24V

Relay cable length
Bus
EAN
Article No
With halogen free relay cable
3.28 ft. (1 m)
BACnet CO
5901688823743
322224-13514
6.56 ft. (2 m)
BACnet CO
5902276896743
322224-13515
16.4 ft. (5 m)
BACnet CO
5901688823767
322224-13516
3.28 ft. (1 m)
Modbus CO
5901688823682
322224-12514
6.56 ft. (2 m)
Modbus CO
5901688823699
322224-12515
16.4 ft. (5 m)
Modbus CO
5901688823705
322224-12516

Additional equipment

Daisy chain cables

A: To connect the first TA-Slider 160/500 BACnet or Modbus of a daisy chain to the Bus.
B: Between two actuators in a daisy chain.
C: To enable hybrid mode or provide power supply if the daisy chain is long.

Cable length
EAN
Article No
Halogen free cable
Type A
4.92 ft (1.5 m)
5902276898228
322042-80012
16.4 ft (5 m)
5902276898235
322042-80013
32.8 ft (10 m)
5902276898242
322042-80014
Type B
4.92 ft (1.5 m)
5902276898259
322042-80015
16.4 ft (5 m)
5902276898266
322042-80016
32.8 ft (10 m)
5902276898273
322042-80017
Type C
4.92 ft (1.5 m)
5902276898280
322042-80018
16.4 ft (5 m)
5902276898297
322042-80019
32.8 ft (10 m)
5902276898303
322042-80020

TA-Dongle

For Bluetooth communication with the HyTune app, transfer configuration settings and manual override.

EAN
Article No
5901688828632
322228-00001

Name Document Type Download All
TA-Slider_160_BACnet_Modbus_US_low.pdf Technical Specifications
TA-Slider_160_BACnet_Modbus_instruction.pdf Installation Instructions
TA-Slider_160_BACnet_CO_Modbus_CO_instruction.pdf Installation Instructions
TA-Dongle_QuickGuide_EN.pdf Installation Instructions
TA-Slider_160-500_BACnet_MS-TP.pdf Bus Protocol Implementations
TA-Slider_160-500_Modbus_RTU.pdf Bus Protocol Implementations
Decl_of_Conf_TA-Slider-160_BACnet_Modbus_CO.PDF Legal Documents
Decl_of_Conf_TA-Dongle.pdf Legal Documents

Ask an Expert


product