Features & Benefits
Complete systems for decentralised heat distribution and hot water
Provides the dwelling with heat, controlling the heat requirements and/or producing hot water via the heat exchanger.
Considerable savings in installation costs
Central risers and decentralised distribution. Domestic hot water flow and return pipes are no longer required.
Lower maintenance costs
No additional costs for consumption settlement, each unit is recorded separately.
One substation for all application scenarious
Through the modular design of the substation it offers an easy adaption to different application. By the aid of accessories it can be converted to fit in different application scenarios like the need for hot water circulation, a hot water temperature limitation or scalding protection.
Technical Information
Applications:
Supply of hot as well as cold water and heating to apartments in multiple-dwelling buildings, hotels, hospitals and elderly homes with actual consumption accounting.
Dimensions:
Draw-off volume 17 l/min (-SLC version 15 l/min) when heating hot water.
Normal conditions with:
Heating supply pipe: 65°C (-SLC version 55°C).
Cold water inlet: 10°C
Hot water outlet: 50°C
Cold water pressure: min. 3 bar
Heat output: 10 kW at ΔT 20K
Pressure class:
PN 10
Temperature:
Max. working temperature: 90°C
Material:
Heat exchanger: Copper soldered stainless steel AISI 316
PM regulator: DZR brass
STAP: AMETAL®
TBV-C: AMETAL®
Piping material: Stainless steel AISI 316L.
Capillary pipes: Copper
Cabinets: Powder-coated sheet steel
General:
More information on STAP, TBV-C and RTL – see separate technical leaflets.
Articles
TA-COMFORT-S for floor heating and drinking hot water purpose
Max. output service water Q [kW] | Draw-off volume (10/50°C) [l/min] | Heat exchanger | Max. pressure loss without heat meter [kPa] | EAN | Article No |
46 | 17 | E8LASHx42/1P | 40 | 5902276834851 | 344030-30011 |
TA-COMFORT-SLC Heat Pump for floor heating and drinking hot water purpose
Max. output service water Q [kW] | Draw-off volume (10/50°C) [l/min] | Heat exchanger | Max. pressure loss without heat meter [kPa] | EAN | Article No |
40 | 15 | E8LASHx42/1P | 45 | 5902276898594 | 326010-30084 |
Frame size 662x850 mmWhite RAL 9016
Flush mounted cabinet with cover, drip tray
Frame size 662x850 mm
White RAL 9016
T | EAN | Article No |
150-240 | 5902276835025 | 344030-40034 |
T = Depth of the complete cabinet
White RAL 9016
Wall mounted cabinet with door
White RAL 9016
EAN | Article No |
5902276834974 | 344030-40029 |
This unit is used for wiring thermostats and electro-thermal actuators. The unit is suitable for underfloor heating and cooling (summer/winter operation). It is possible to switch over between heating and cooling via an external signal. The pump logic enables enery-optimised pump control. For up to 6 zones (rooms). Ready to plug in to a 230 V power socket.
Distributor strip
This unit is used for wiring thermostats and electro-thermal actuators. The unit is suitable for underfloor heating and cooling (summer/winter operation). It is possible to switch over between heating and cooling via an external signal. The pump logic enables enery-optimised pump control. For up to 6 zones (rooms). Ready to plug in to a 230 V power socket.
EAN | Article No |
4024052891115 | 1612-00.000 |
Support rails for floor heating distributors.With connection pipe set to the Dynacon distributor.Frame size 664x1383 mmWhite RAL 9016
Flush mounted cabinet with cover
Support rails for floor heating distributors.
With connection pipe set to the Dynacon distributor.
Frame size 664x1383 mm
White RAL 9016
T | Max. outlets | EAN | Article No |
With drip tray | |||
150-240 | 8 | 5902276896422 | 344030-40037 |
T = Depth of the complete cabinet
White RAL 9016
Wall mounted cabinet
White RAL 9016
T | EAN | Article No |
200 | 5902276834912 | 344030-40023 |
260 | 5902276834981 | 344030-40030 |
T = Depth of the complete cabinet
A. 7 x female Rp3/4 B. 3 x male G3/4 and 4 x female Rp3/4C. Subbase without ball valves (plugged)
Subbase with 7 ball valves
A. 7 x female Rp3/4
B. 3 x male G3/4 and 4 x female Rp3/4
C. Subbase without ball valves (plugged)
EAN | Article No | ||
A | 7 x Rp3/4 | 5902276834967 | 344030-40028 |
B | 3 x G3/4 + 4 x Rp3/4 | 5902276896439 | 344030-40046 |
C | 7 x plugs | 5902276896170 | 344030-40047 |
Frame size 662x850 mmWhite RAL 9016
Flush mounted cabinet with cover
Frame size 662x850 mm
White RAL 9016
T | EAN | Article No |
150-240 | 5902276834998 | 344030-40031 |
T = Depth of the complete cabinet
Ball valves for tap water connection; 3 x male G3/4 for tap water, flat sealing.4 x female Rp3/4 for heating part, 7 gaskets.Frame size 662x850 mmWhite RAL 9016
Flush mounted cabinet with cover, drip tray with mounting bracket and 7 ball valves
Ball valves for tap water connection;
3 x male G3/4 for tap water, flat sealing.
4 x female Rp3/4 for heating part, 7 gaskets.
Frame size 662x850 mm
White RAL 9016
T | EAN | Article No |
150-240 | 5902276834929 | 344030-40024 |
T = Depth of the complete cabinet
Support rails for floor heating distributors.Drip tray with pipe connections.Ball valves for tap water connection; 3 x male G3/4 for tap water, flat sealing.2 x female Rp3/4 for heating part, 7 gaskets.2 x male G3/4 with connection pipe set to the Dynacon distributor.Frame size 664x1383 mmWhite RAL 9016
Flush mounted cabinet with cover, drip tray with mounting bracket and 7 ball valves
Support rails for floor heating distributors.
Drip tray with pipe connections.
Ball valves for tap water connection;
3 x male G3/4 for tap water, flat sealing.
2 x female Rp3/4 for heating part, 7 gaskets.
2 x male G3/4 with connection pipe set to the Dynacon distributor.
Frame size 664x1383 mm
White RAL 9016
B | T | Max. outlets | EAN | Article No |
610 | 150-240 | 8 | 5902276835018 | 344030-40033 |
810 | 150-240 | 12 | 5901688829035 | 344030-40038 |
T = Depth of the complete cabinet
Dynacon 150 underfloor heating circuit manifold
Heating circuits | EAN | Article No |
2 | 4024052053223 | 9346-02.800 |
3 | 4024052053322 | 9346-03.800 |
4 | 4024052053421 | 9346-04.800 |
5 | 4024052053520 | 9346-05.800 |
6 | 4024052053629 | 9346-06.800 |
7 | 4024052053728 | 9346-07.800 |
8 | 4024052053827 | 9346-08.800 |
9 | 4024052053926 | 9346-09.800 |
10 | 4024052054022 | 9346-10.800 |
11 | 4024052054121 | 9346-11.800 |
12 | 4024052054220 | 9346-12.800 |
Straight: With swivelling nut and flat sealing for the station side.Angle: With cylindric external thread and flat sealing for the station side.
Ball valves
Straight: With swivelling nut and flat sealing for the station side.
Angle: With cylindric external thread and flat sealing for the station side.
Type | EAN | Article No | ||
Straight | Male | G3/4 | 5902276835056 | 344030-40054 |
Straight | Female | Rp3/4 | 5902276835063 | 344030-40055 |
Angle | Male | R3/4 | 5902276835070 | 344030-40056 |
Cover safe for wall mounted cabinets
EAN | Article No |
5902276835117 | 344030-40061 |
230 V
EMO T actuator
230 V
Type | Cable length [m] | EAN | Article No |
EMO T, NO (Normally open) | 0,8 | 4024052836611 | 1837-00.500 |
EMO T, NC (Normally closed) | 0,8 | 4024052835416 | 1833-00.500 |
For installing the room thermostat onto UP boxes. White RAL 9010.83 mm x 83 mm x 8 mm (W x H x D).
Distance plate
For installing the room thermostat onto UP boxes. White RAL 9010.
83 mm x 83 mm x 8 mm (W x H x D).
EAN | Article No |
4024052408719 | 1936-00.433 |
Thermostat P, with analog timer
Model | EAN | Article No |
230 V | 4024052405718 | 1932-00.500 |
Room thermostat
Model | EAN | Article No | |
230 V | |||
Without temperature set-back | 4024052405916 | 1936-00.500 | |
With temperature set-back | 4024052406111 | 1938-00.500 |
Model | EAN | Article No | |
230 V | |||
With On/Off switch | 1939-00.500 |
Thermostat P, with digital timer
Model | EAN | Article No |
230 V | 4024052763610 | 1932-01.500 |