Features & Benefits

    High efficiency independent of dimension

    Separation efficiency increases together with flow velocity. The pressure drop remains stable regardless of the amount of dirt collected. Even higher protection for higher flows, e.g. in cooling applications. Suitable for up to 300 kW of system output.

    Cleans and protects the installation

    Protects critical investments such as boilers, pumps, valves, chillers, and calorie meters, from dirt-related malfunction and failure. No risk of clogging - the dirt collected can be easily and quickly flushed out with the help of the drain valve. Reduces maintenance and associated costs over entire system lifetime.

    Magnet Accessory

    Optimises separation efficiency even further for sludge and magnetite (black iron oxide) deposits that consist of finer magnetic particles. Combines magnetic separation and thermal insulation. Available in a set with the Zeparo Cyclone or as a separate accessory.

    Horizontal and vertical mounting

    The unique cyclonic technology works in every position, allowing the Zeparo Cyclone to be mounted in vertical pipes as well.

    Technical description

    Application:

    Heating and chilled water systems.

    Media:

    Non-aggressive and non-toxic system media.
    Ethylene or propylene glycol-based antifreeze up to 50%.

    Pressure:

    Max. admissible pressure, PS: 10 bar
    Min. admissible pressure, PSmin: 0 bar

    Temperature:

    Max. admissible temperature, TS: 120 °C
    Min. admissible temperature, TSmin: -10 °C

    Material:

    Body: Brass
    Cyclone insert: PPS Ryton.
    Gaskets: EPDM

    Marking:

    Body: PN, DN, flow direction arrow.
    Label with TS and TSmin.

    Transportation and storage:

    In dry places.

    Magnet and Thermal insulation:

    Magnet: NdFeB with Ni-Cu-Ni cover/protection against rust.
    Insulation: Expanded polypropylene (EPP), anthracite.
    Insulation value approx. 0.035 W/mk.
    Fire rating B2 to DIN 4102 and E in acc. to EN 13501-1.
    Max. temperature: 110 °C.
    Min. temperature: 6-8 °C (above dew point).

    Zeparo Cyclone Dirt ZCD – Separator, version Dirt for sludge particles

    Horizontal and vertical installation.

    Zeparo Cyclone ZCD

    Horizontal and vertical installation.

    Female thread according to ISO 228. DN 20 thread length according to ISO 7/1.

    Type
    H
    h1
    L
    qnom
    [m3/h]
    qmax
    [m3/h]
    m
    [kg]
    D
    EAN
    Article No
    ZCD 20 *
    201
    305
    100
    1,18
    2,3
    1,3
    G3/4
    7640153570543
    789 7420
    ZCD 25
    201
    305
    100
    1,47
    3,8
    1,3
    G1
    7640153570550
    789 7425
    ZCD 32
    258
    355
    122
    3,18
    7,2
    2,2
    G1 1/4
    7640153570567
    789 7432
    ZCD 40
    310
    400
    158
    4,75
    10,2
    3,7
    G1 1/2
    7640153570574
    789 7440
    ZCD 50
    310
    400
    160
    6,88
    16,0
    3,9
    G2
    7640153570581
    789 7450

    *) Can be connected to smooth pipes by KOMBI compression coupling.

    qmax calculated on max speed in the pipe of 2 m/s.

    Horizontal and vertical installation.

    Zeparo Cyclone ZCDF

    Horizontal and vertical installation.

    Flanges according to EN 1092-1.

    Type
    DN
    H
    h1
    L
    qnom
    [m3/h]
    qmax
    [m3/h]
    m
    [kg]
    D
    EAN
    Article No
    ZCDF
    50
    325
    400
    230
    6.88
    16.0
    8.78
    165
    5902276895135
    303040-80902

    *) Can be connected to smooth pipes by KOMBI compression coupling.

    qmax calculated on max speed in the pipe of 2 m/s.

    Zeparo Cyclone ZCDM Sets

    Horizontal and vertical installation.

    ZCD + ZCHM

    Horizontal and vertical installation.

    Type
    H
    h1
    L
    B
    m
    [kg]
    D
    Number of magnets
    EAN
    Article No
    20 *
    213,5
    305
    100
    110
    1,4
    G3/4
    4
    7640153570598
    789 7520
    25
    213,5
    305
    100
    110
    1,4
    G1
    4
    7640153570604
    789 7525
    32
    269,5
    355
    122
    132
    2,4
    G1 1/4
    4
    7640153570611
    789 7532
    40
    327,2
    400
    158
    160,5
    3,9
    G1 1/2
    6
    7640153570628
    789 7540
    50
    327,2
    400
    160
    160,5
    4,2
    G2
    6
    7640153570635
    789 7550

    *) Can be connected to smooth pipes by KOMBI compression coupling. See catalogue leaflet KOMBI.

    qmax calculated on max speed in the pipe of 2 m/s.

    Accessories

    Max.: 100°CThrust screw: AMETAL® or brass, nickel plated.Cone: Brass(For more information see catalogue leaflet KOMBI.)

    KOMBI compression coupling

    Max.: 100°C
    Thrust screw: AMETAL® or brass, nickel plated.
    Cone: Brass
    (For more information see catalogue leaflet KOMBI.)

    Male pipe threads
    on thrust screw
    For pipes,
    diameter
    EAN
    Article No
    G3/4
    15
    7318792875403
    53 235-117
    G3/4
    18
    7318792875601
    53 235-121
    G3/4
    22
    7318792875700
    53 235-123

    Support bush should be used TA 320 for copper pipes and TA 321 for steel pipes, see catalogue leaflet KOMBI.

    The insulation with magnet can be mounted on the Zeparo Cyclone without draining the system. Also compatible with the flanged ZCDF.

    Magnet and Thermal insulation ZCHM

    The insulation with magnet can be mounted on the Zeparo Cyclone without draining the system. Also compatible with the flanged ZCDF.

    Type
    Size
    H
    L
    B
    Number of magnets
    m
    [kg]
    EAN
    Article no
    ZCHM 20-25
    DN 20-25
    175
    108
    110
    4
    0,126
    7640161629158
    787 7425
    ZCHM 32
    DN 32
    232
    132
    134
    4
    0,189
    7640161629202
    787 7432
    ZCHM 40-50
    DN 40-50
    289
    158,5
    160,5
    6
    0,310
    7640161629219
    787 7450

    To select a Zeparo Cyclone with magnet you have to order a Zeparo Cyclone ZCD and an insulation with magnet ZCHM in the same dimension or use the set ZCDM.

    78774xx_ZCHM

    Select a format Download

    Zeparo_Cyclone_cat_front

    Select a format Download

    Zeparo_Cyclon_ZCD_7897432

    Select a format Download

    Zeparo_Cyclone_ZCDM

    Select a format Download

    Zeparo_Cyclon_ZCD_small_w_path

    Select a format Download

    7897432

    Select a format Download